DemirDöküm Boiler Error Codes

Aden Boiler Error Codes

  • F0: Low water pressure in the boiler.
  • F1: Overheat thermostat malfunction.
  • F2: Hot water NTC sensor malfunction.
  • F4: The boiler does not ignite.
  • F5 – F6: Airflow issue, flue or air pressure switch malfunction.
  • Oc: Air pressure switch remains engaged.
  • Cc: Air pressure switch or flue sensor deactivated.

Atron Boiler Error Codes

  • F1: Overheating issue.
  • F2: Hot water NTC sensor malfunction.
  • F3: Fault in the sensor measuring the water supplied to the heating system.
  • F4: The boiler does not ignite.
  • F5: Airflow issue.
  • F6: Circulation sensor malfunction.
  • F7: Gas valve malfunction.
  • F8: Overheating in the temperature sensor.
  • F9: Short circuit in the air pressure switch.
  • F10: Very low water pressure.
  • F11: No water circulation.
  • F12: Voltage below 165V.
  • F13: Issue with temperature difference between flow and return sensors.

İsofast Boiler Error Codes

  • F01 / F04: The boiler does not ignite.
  • F02: Airflow is not ensured.
  • F03: Pressure switch issue.
  • F05: Overheating issue.
  • F06: Radiator sensor malfunction.
  • F07: Hot water sensor malfunction.
  • F08: Radiator sensor malfunction.
  • F09: Hot water sensor failure.
  • F10: Return water sensor malfunction.
  • F11: No signal from the main board.
  • F12: Display board is not receiving signals.
  • F13: Main board issue.
  • F14: Water temperature exceeds 95°C.
  • F15: Three-way valve step motor issue.
  • F16: The burner remains on even after shutting down.
  • F17: Voltage below 170V.
  • F18: Display board malfunction.
  • F19: Radiator sensor not connected.
  • F20: Incompatibility between the main board and the display board.
  • F21: No water circulation.
  • F23: Rapid increase in radiator circuit water temperature.

Millenium Plus Boiler Error Codes

  • F1 / F4: The boiler does not ignite.
  • F2: Air pressure switch issue.
  • F3: Air pressure switch malfunction.
  • F5: Limit sensor malfunction.
  • F6: Hot water sensor malfunction.
  • F9: Radiator sensor issue.
  • F11: Electronic board malfunction.
  • F12: Display board malfunction.
  • F13: Main board issue.
  • F14: Radiator water temperature exceeds 95°C.
  • F15: Three-way valve step motor issue.
  • F16: The flame continues even though the boiler should be off.
  • F17: Low voltage.
  • F19: Hot water NTC sensor not attached to the pipe.
  • F20: Display board incompatibility.
  • F21: Very low water pressure.
  • F22: Excessive water pressure.

Nitron Boiler Error Codes

  • F1: Limit thermostat issue.
  • F2: Hot water NTC sensor malfunction.
  • F4: The boiler does not ignite.
  • F5: Airflow issue.
  • F6: Outdoor air sensor malfunction.
  • F7: Airflow sensor connection problem.
  • F8: Fan motor malfunction.
  • F9: Wiring problem.
  • F10: Very low water pressure.
  • F11: No water circulation.
  • F12: Low voltage.

Solaris Boiler Error Codes

  • F0: Low water pressure in the boiler.
  • F1: Overheat thermostat malfunction.
  • F2: Hot water sensor malfunction.
  • F4: The boiler does not ignite.
  • F5 / F6: Airflow issue.
  • Oc: Flue or air pressure switch issue.
  • Cc: Flue or air sensor deactivated.

Nitromix Boiler Error Codes

  • F00 / F10: Flow temperature sensor issue.
  • F01 / F11: Return temperature sensor issue.
  • F20: Overheating issue.
  • F22: Low water pressure.
  • F23: Circulation issue.
  • F26: Gas valve issue.
  • F27: Flame detection issue.
  • F28: No gas supply.
  • F29: Gas supply cut off.
  • F32: Fan speed issue.
  • F49: Voltage issue.
  • F61 - F67: Main board issue.
  • F68: Flame signal fluctuation.
  • F70: Incompatibility between control boards.
  • F71: Water flow sensor issue.
  • F72: Flow and return sensors temperature difference issue.
  • F73 / F74: Pressure sensor malfunction.
  • F76: Thermal fuse issue.
  • F77: Gas valve motor issue.
  • F83: Burner is running, but temperature does not rise.
  • F84: Maximum temperature difference issue.
  • F85: Sensor issue.
  • F86: Underfloor heating contact issue.
  • Err: User interface issue.

Themafast Boiler Error Codes

  • F01 / F04: The boiler does not ignite.
  • F02: Air pressure switch issue.
  • F03: Air pressure switch malfunction.
  • F05: Overheating issue.
  • F06: Radiator sensor issue.
  • F08: Flow temperature sensor issue.
  • F09: Pressure sensor issue.
  • F11: Main board issue.
  • F12: Display board issue.
  • F13: Electronic board malfunction.
  • F14: Sensor issue.
  • F15: Three-way valve step motor issue.
  • F16: Gas valve issue.
  • F17: Low voltage.
  • F18: Display board issue.
  • F19: Sensor is not connected to the pipe.
  • F20: Display board incompatibility.
  • F21: Low water pressure.
  • F22: Excessive water pressure.

Vinto Boiler Error Codes

  • F01 / F04: The boiler does not ignite.
  • F2: Airflow issue.
  • F3: Air pressure switch malfunction.
  • F5: Overheating issue.
  • F6: Radiator sensor issue.
  • F9: Radiator circulation water sensor issue.
  • F11: No signal from the electronic board.
  • F12: Display board issue.
  • F13: Main board malfunction.
  • F14: Radiator circulation water temperature exceeds 95°C.
  • F15: Three-way valve step motor issue.
  • F16: The flame continues even though the boiler is off.
  • F17: Low voltage.
  • F18: Display board malfunction.
  • F19: Hot water sensor is not connected to the pipe.
  • F20: Display board incompatibility.
  • F21: Low water pressure.
  • F22: Excessive water pressure.
If you are unable to resolve the issue using the error codes, please contact us!